From 66322b689e46520647e2d94d5e3f3ce282a41247 Mon Sep 17 00:00:00 2001 From: Richard Purdie Date: Wed, 26 Jun 2019 17:24:19 +0100 Subject: oeqa/runtime/syslog: Add delay to test to avoid failures On a loaded builder we've seen the log message not make it to the log file before the ssh command completes. Add a short delay to try and ensure this does happen. There is unforunately no way to flush syslog in all cases we test. Signed-off-by: Richard Purdie --- meta/lib/oeqa/runtime/cases/oe_syslog.py | 3 +++ 1 file changed, 3 insertions(+) diff --git a/meta/lib/oeqa/runtime/cases/oe_syslog.py b/meta/lib/oeqa/runtime/cases/oe_syslog.py index 449df233d1..3a8271a53a 100644 --- a/meta/lib/oeqa/runtime/cases/oe_syslog.py +++ b/meta/lib/oeqa/runtime/cases/oe_syslog.py @@ -85,6 +85,9 @@ class SyslogTestConfig(OERuntimeTestCase): msg = "Can't log into syslog. Output: %s " % output self.assertEqual(status, 0, msg=msg) + # There is no way to flush the logger to disk in all cases + time.sleep(1) + status, output = self.target.run('grep foobar /var/log/messages') if status != 0: if self.tc.td.get("VIRTUAL-RUNTIME_init_manager") == "systemd": -- cgit 1.2.3-korg